何为DVR动态电压恢复器?
动态电压恢复器(DVR)采用全控型电力电子器件IGBT,核心组成包括储能元件(超级电容)、逆变器、充电单元切换开关及旁路开关。其接入系统的方式独具特点:逆变器采用并联设计,切换开关则串联在供电电源与受保护负载之间,形成高效的电压保障链路。当电网出现电压暂降、暂升或短时中断等异常情况时,DVR 会立即切断输入侧电源,同时从自带的储能器件中汲取所需能量。通过三相桥式逆变电路系统,它能快速生成与电网电压幅值、相位完全一致的补偿电压,无缝输送至负载端,确保输出电压瞬间恢复至额定值,实现负载供电零中断,为设备稳定运行提供坚实保障。作为储能式电压补偿设备,其显著优势在于适应性极强 —— 无论单相、两相或三相电压跌落,即便跌落至 0%,都能有效治理,始终为负载提供合格电能,保障用电安全可靠。动态电压恢复器主要有四种工作状态:电网正常时:待机模式此时 DVR 的晶闸管电子开关导通,负载直接由电网供电,既保证高效运行,又实时监测电网状态。电网异常时:补偿模式当发生电压暂降、骤升或短时中断,设备会快速切断晶闸管电子开关,同步启动IGBT 功率模块,使负载与电网隔离,转而由 DVR 独立供电,实现快速响应与隔离输出。电网恢复稳定:恢复模式DVR 先将输出电压波形与电网波形同步,随后接通晶闸管电子开关,让负载重新由电网直接供电;同时,系统会为储能电容柜补充损耗的能量,整个过程柔性退出、无缝切换。故障或检修时:旁路模式若 DVR 出现故障或需要技术检修,会自动切换至旁路回路供电;待维护完成后,设备将自动恢复正常运行,体现快速旁路与自动复位的优势。What is Dynamic Voltage Restorer ?The Dynamic Voltage Restorer (DVR) adopts IGBT, a fully-controlled power electronic device, with core components including energy storage elements (supercapacitors), an inverter, a charging unit changeover switch, and a bypass switch. Its way of connecting to the system is unique: the inverter is designed in parallel, and the changeover switch is connected in series between the power supply and the protected load, forming an efficient voltage protection link.When the power grid has abnormal conditions such as voltage sag, swell, or short-term interruption, the DVR will immediately cut off the input-side power supply and at the same time draw the required energy from its own energy storage device.Through the three-phase bridge inverter circuit system, it can quickly generate a compensation voltage that is completely consistent with the amplitude and phase of the grid voltage, and seamlessly transmit it to the load end, ensuring that the output voltage instantly returns to the rated value, realizing zero interruption of load power supply, and providing a solid guarantee for the stable operation of the equipment.As an energy storage voltage compensation device, its significant advantage lies in its strong adaptability - no matter the voltage drop of single-phase, two-phase or three-phase, even if it drops to 0%, it can be effectively controlled, and it always provides qualified electric energy for the load, ensuring safe and reliable power consumption.The Dynamic Voltage Restorer mainly has four working states:When the power grid is normal: Standby ModeAt this time, the thyristor electronic switch of the DVR is turned on, and the load is directly powered by the power grid, which not only ensures efficient operation but also monitors the grid status in real-time.When the power grid is abnormal: Compensation ModeWhen a voltage sag, swell, or short-term interruption occurs, the device will quickly cut off the thyristor electronic switch, synchronously start the IGBT power module, isolate the load from the power grid, and then switch to independent power supply by the DVR, achieving rapid response and isolated output.When the power grid returns to stability: Recovery ModeThe DVR first synchronizes the output voltage waveform with the grid waveform, then turns on the thyristor electronic switch to allow the load to be directly powered by the grid again; at the same time, the system will supplement the lost energy for the energy storage capacitor cabinet, and the whole process is flexibly exited and seamlessly switched.During failure or maintenance: Bypass ModeIf the DVR fails or needs technical maintenance, it will automatically switch to the bypass circuit for power supply; after the maintenance is completed, the device will automatically resume normal operation, reflecting the advantages of fast bypass and automatic reset.
发布:2025-07-28 浏览:56
新能源充电桩功率因素问题
超级充电站是一种为电动汽车提供电能的装置,使电动汽车能够存储足够的电量以支持其运行。充电桩现场大多建设在郊区,充电桩的充电频率过低会造成变压器轻载运行时间过多。现场同时出现感性无功和容性无功、功率因数过低同时出现的情况。通常有车充电的时候正常,没有车充电时功率因数就很低。充电桩其实就是把交流电转化为直流电进行一个充电的过程,是一个整流回路,整流过程中必然会改变电流的波形而产生谐波。如果单纯的电容补偿,很容易出现控制器的干扰,导致过补现象。功率因数出现负数,充电桩补偿柜的负载变化频繁,会导致电网电压的电流波动,从而影响电网的稳定性和可靠性。充电桩是属于容性设备,模块里面有很多的电容配件,待机时它会产生无功电流、无功功率;如果充电桩的充电量少了,整体的功率因数低于0.85,那就会被加收力调电费。此时需要加装SVG设备,通过实时监测电网的电压,电流等参数,并根据需要在短时间内发生无功电流来补偿电网中的无功功率,使电网中的电压和电流更稳定,避免力调电费罚款。Power factor issue of new energy vehiclesA supercharging station is a facility designed to provide electrical energy to electric vehicles, enabling them to accumulate sufficient power for their operation. Most of these stations are situated in suburban areas. A low charging frequency at these stations often results in transformers operating under light load for extended periods. On-site, both inductive and capacitive reactive power issues, coupled with a low power factor, arise simultaneously.Typically, the power factor remains normal when a vehicle is being charged, but drops significantly when no vehicle is charging. A charging pile essentially involves converting alternating current (AC) to direct current (DC) for the purpose of charging, functioning as a rectification circuit. Inevitably, this conversion process alters the current waveform, resulting in the generation of harmonics.If pure capacitive compensation is employed, it often leads to controller interference, resulting in overcompensation. A negative power factor, coupled with frequent load variations in the compensation cabinet of charging piles, can induce voltage and current fluctuations in the power grid, impacting its stability and reliability. Charging piles are capacitive devices, equipped with numerous capacitor components within their modules. In standby mode, they generate reactive current and reactive power. If the charging capacity of the charging piles decrease, causing the overall power factor to fall below 0.85, additional surcharges for power factor adjustment will be imposed on the electricity bill.At this juncture, it is necessary to install SVG equipment, which monitors the voltage, current, and other parameters of the power grid in real time. Depending on requirements, it can generate reactive current promptly to compensate for reactive power in the grid, thereby stabilizing the voltage and current and preventing penalties for power factor adjustment.
发布:2025-07-21 浏览:189
医用隔离变压器是什么原理?
医用隔离电源系统的主要作用是保护患者、医护人员的安全及提供稳定的电力供应,通过将传统市电系统转化为不接地系统,使得在发生故障时也能持续输出电力,正常在手术室、ICU这样的特殊环境下使用。医用隔离变压器输入电压等于输出电压,安装后可以消除直接电的联系。正常电力系统中,一根电线是相线,一根电线是零线(中性线)。由于中性线是接地线,因此它和大地同电位,当人体接触大地的同时,在初级象限就会使电流通过人体和大地构成回路,造成触电危险。医用隔离变压器初级、次级是通过磁场交换能量的,没有物理上的连接,二次两根线都不会接地。因此,人站在大地上接触二次任意一根线,都和大地没有电位差,不会发生触电事故。
发布:2025-07-11 浏览:121
HDA-SDVR抗晃电模块是什么原理?
电力系统运行中,由于外部线路遭受雷击、瞬时短路、中断等故障,可能会引起企业内部电网的相邻线路发生短路故障,或者由于大型电动机启动等原因,导致电压出现短暂而显著的波动后又恢复稳定,这种现象通常被称为“晃电”。晃电现象通常有以下几种表现形式:A、电压突变,包括骤降和骤升,持续时间通常在0.5个周期至1分钟之间,电压可能上升至标称电压的110%至180%,或者下降至标称电压的10%至90%。B、电压闪变,即:电压波形的包络线呈现出规则性变化,或者电压幅值发生一系列随机变化,这种现象通常表现为人们视觉上对电压波动导致的照明异常的感知。C、短时断电,即:持续时间为0.5个周期至3秒的供电中断。常规意义上讲,治理从源头到生产线,再到单台设备乃至电气控制元件,成本随层级深入而显著降低;基于成本效益和效果,建议在设备末端或其电气控制元件进行治理;因为这样成本更低且效果相同,治理重点是解决低压系统中设备的电压暂降问题。一、接触器回路的晃电问题治理方案UPS供电:利用不间断电源(UPS)确保电源侧的稳定供电;防晃电接触器:选用具备防晃电功能的接触器,以减少晃电对电路的影响;再起动控制:通过电动机保护器等设备,在二次控制回路中实现对电动机的再起动控制;抗晃电装置:应用专用模块对接触器进行保持和控制,以增强电路对晃电的抵抗力。二、变频器、软起动晃电治理方案多数变频器配备了过压、欠压以及瞬时停电保护功能,变频器的逆变部分通常采用IGBT作为其核心器件,在遇到电压下降或停电的情况下,变频器能够维持短暂的运行时间TD。然而,如果电压下降或停电的持续时间TOTD超出了预设的安全范围,变频器将启动自我保护机制,停止运行。变频器常见治理方案:UPS供电、变频器自启动、直流支撑技术、控制电路失压再起动、软启动器广泛应用于工业领域,特别是在45kW以上的大功率电机场合,它集成了软启动、软停车以及多种保护功能,旨在确保电机在启动过程中平稳无冲击,避免启动时产生过大电流,从而保护电机的正常运行并延长其使用寿命。与变频器相比,软启动器本质上是一个电压调节器,不具备频率和速度调节的能力;尽管如此,变频器几乎涵盖了软启动器的所有功能;因此,适用于变频器的晃电再启动功能的HDA-SDVR-200型号,同样适用于软启动器的晃电再启动。综上所述,在选择一款合适的抗晃电模块时,需要考虑功率和电流参数、稳定性和响应速度、保护功能、可靠性和耐用性等方面;最终解决电机和变频设备晃电停机等问题,提高电力系统的稳定性和可靠性。
发布:2025-06-30 浏览:180
什么情况下需要做谐波检测?
电力系统中谐波无处不在,谐波的存在是一个非常大的安全隐患,尤其是关于机房、精密厂房、冶炼车间这样的场所;电力体系中是否存在谐波,必须通过专业工具来测试,进而再考虑谐波治理的方案。电能质量分析仪可以提供电力运行中的谐波分析,能够对电网进行长时间的数据采集监测,同时配备电能质量数据分析软件,对上传至计算机的测量数据进行各种方案制定。通常如果出现以下七种情况说明需要做谐波检测:一、变压器噪声异常且出现明显抖动,负荷率不高,发热却比较严重;二、零线电流比相线电流大,发热严重,且有时出现零线烧毁的现象;三、照明灯具频发闪烁,电压不稳,忽高忽低,难以保持平衡;四、天气变热的情况下,线路设备出现跳闸、停机、烧毁的情况;五、补偿柜中电容器频繁损坏,且电抗器发热异常,伴随严重噪音;六、精密制造设备的次品率异常增加,生产线故障频繁出现;七、光伏并网后出现力调电费的罚款单,甚至逆变器会出现烧毁状况 。
发布:2025-06-24 浏览:214
什么是三次谐波、五次谐波?
周期波形是指一种具有重复性的波形,它在一定的时间周期内呈现相同的形状和变化。在交流电路中,电压、电流通常是按照正弦波规律作变化的,频率为50赫兹,代表1秒钟内重复变化了50次;以50赫兹为参考,这就是基波。当正弦波发生畸变时,通过傅里叶级数分解,就可以把它分解出基波和高次谐波,如:150Hz的3次谐波,250Hz的5次谐波,所谓的3次、5次是指对基波频率的倍数,畸变越严重,谐波的占比就越大。
发布:2025-06-16 浏览:303
什么是UPQC电能质量综合治理装置?
HDA-UPQC电能质量综合治理装置适用于需要瞬时无功补偿的应用中,可提供容性或感性的无级补偿;也可以根据负载需求自动调节,实现双向无功补偿、三相不平衡和谐波治理。其主要有以下几点优势:1、可实现智能双向线性调节无功功率,抑制电压闪变;2、具备2-25次滤波功能,既能快速无功补偿,又有一定谐波治理能力;3、确保即使在负载不平衡的情况下,供电系统也能够保持负载均衡;4、加强系统电压稳定性,抑制因负载侧导致的电压波动和闪变;5、采用模块化设计,可混合搭配,覆盖 15-1200kvar的补偿需求;6、响应速度低至 10 ms,有效应对负载动态变化,超强静音。
发布:2025-06-13 浏览:239
针对中频炉如何进行10kV谐波治理?
中频炉是一种将工频50HZ交流电转变为中频(300-1000HZ)的电源装置,把三相工频交流电整流后变成直流电,再将直流电变成可调节的中频电流,供给由电容、感应线圈里流过的中频交变电流。在感应圈中产生高密度的磁力线,切割感应线圈里盛放的金属材料,在金属材料中产生较大的涡流,整体来说是一个重熔过程。通常按照容量将中频炉分为两类:小型中频炉(3吨以下)、大中型中频炉(5吨以上)。江苏省盐城市一用户有数台小型中频炉,供电架空线路长达5公里,此线路是一条公共线路,除了中频炉负荷以外,还有农民的用电负荷,中频炉生产时的谐波经常损坏其他用户的设备,跳闸和烧毁情况时有发生。使用专用设备进行检测后,制作5次、7次、11次、13次的无源滤波装置,烧毁设备的情况得到缓解。针对大中型中频炉来说,谐波分为两类:一类是特征谐波,如24脉,其特征谐波就是23、25;由于该中频炉容量较大,因此谐波也较大;且次数比较高,对电压畸变率的影响突出,容易烧毁设备。另一类谐波是低次的间谐波,这种谐波非常容易烧毁滤波器本身,甚至有时滤波器运行后,其自身就无法正常工作,通过针对性的谐波治理方案,可有效降低中频炉对电网和周边设备的影响,保障公共线路安全稳定运行。
发布:2025-06-03 浏览:217
一只电能表诠释企业的四种用电情况
智能电能表左上角的十字坐标,构建起了一个精妙的数学模型:横轴代表有功功率 P(左负右正);竖轴代表无功功率 Q(上正下负);这两条相互垂直的轴线,将坐标平面划分为四个象限。一象限(+P,+Q):输入有功功率、无功功率,电网向用户送电,电流滞后于电压,用户为感性负载。二象限(-P,+Q):当光伏发电量超越企业自身用电量时,用户摇身一变成为发电端,不仅向电网反送有功功率,同时还从电网获取无功功率。三象限(-P,-Q):当企业内部负载近乎为零,且具备强大的发电能力时,企业便如同一个独立的发电厂,不仅向电网输送有功功率,还输出无功功率。四象限(+P,-Q):企业从电网获取有功功率保障设备运行,却向电网反送无功功率,用电性质为容性负载,通常是由于电力电容过补偿导致。对于传统工业企业,通过分析第一、四象限的用电数据,能够优化无功补偿装置的配置;对于新能源发电企业,第二、三象限的数据则是评估发电效益、协调余电上网的关键依据。
发布:2025-06-03 浏览:280
光伏并网后产生力调电费怎么办?
湖南省湘潭市一用户安装了分布式光伏后,力调电费由原来的奖励3800元变成了罚款4800元,这是为什么呢?首先,我们知道电费单上当力调电费为负数时,就是表示供电局给予用电相应的奖励,会从电费总额中进行扣除。功率因数奖、罚规定:功率因数标准为0.9,每低于标准0.01时,从电费总额罚款0.5%,以此递增,低于0.7每一级提高到1%,低于0.65每级提高到2%;每高于标准0.01,从电费总额奖0.15%,以此类推,以0.75%封顶。其次,要弄清楚现场光伏并网点是在进线柜的采样互感器前端(进线侧),还是在出线柜(负载侧);如果是前者,市电的有功功率、光伏发电的有功功率叠加,会引发功率因素控制器采样不准的问题。如果是后者,此时需更换光伏专用四象限功率因数控制器;同时,如果发电量大于用电量,会引发无功倒送的问题,产生力调电费罚款;这时需要安装SVG,通过检测系统中所需无功,快速发出大小相等、相位相反的无功,实现无功的就地平衡。
发布:2025-05-12 浏览:501